Description
Model:W-T2008-B
Brand: ADVANCED HEALTH CANADA
Country of origin: CANADA
Blood Dialysis Machine W-T2008-B
W-T2008-B blood dialysis machine adopted a closed volume balance chamber, accurate ultrafiltration dehydration control; One-key low-speed ultrafiltration can set low-speed UF, low-speed UF working time, and return to normal UF speed automatically after execution; Support isolated UF can modify the executed time and UF volume based on requirements while isolated UF.
This blood dialysis machine features an Intelligent automatic disinfection and cleaning procedure. It can effectively prevent the deposition of calcium and protein in the pipeline of the machine, unnecessary to use sodium hypochlorite to remove protein which avoids the injury to medical personnel during the use of sodium hypochlorite.
The main performance of this device:
- Self-checking function;
- Carbonate dialysis;
- Double-needle dialysis;
- Liquid level detector;
- Bubble detector;
- Blood leakage detector;
- Temperature and electric conductivity monitoring;
- Arterial pressure, venous pressure, and transmembrane pressure monitoring;
- Rolling blood pump;
- Heparin pump;
- Dehydration amount controlled by capacity;
- Automatic disinfection cleaning program;
- Stand-by power of blood pump in case of power failure;
- Information display function of the display screen.
Specification
General data:
Dimensions | 1420 x 460 x 650 mm (H x W x D) |
Net Weight approx | 88 KG |
Package dimensions | 580×750×1580mm (L x W x H) |
Gross Weight approx | 110KG |
Water supply
Water inlet pressure | 1.5-6.0 bar |
Water inlet temperature | 5℃~32℃ |
Max. drain height | 1m |
Concentrate supply
Supply pressure: 0 to 2 m suction height
Electrical data
Power supply: AC220V±10%, 47-63HZ
Current consumption max.: max. 10 A
Extracorporeal circuit
Arterial pressure monitoring
Display range | -380 mmHg to +400 mmHg |
Accuracy | ±10 mmHg |
Resolution | 1 mmHg |
Venous pressure monitoring
Display range | -180 mmHg to +600 mmHg |
Accuracy | ±10 mmHg |
Resolution | 1 mmHg |
Transmembrane pressure monitoring
Display range | -180 mmHg to +600 mmHg |
Accuracy | ±20 mmHg |
Resolution | 1 mmHg |
Arterial blood pump
Blood flow ranges: from 30 to 600ml/min in 8 mm bloodline systems
Accuracy: ±10%
Air bubble pump
By ultrasound transmission, additional optical monitoring in the venous clamp.
Heparin pump
Delivery range | 0ml/h to 10ml/h |
Bolus function max. | 20 mL per bolus |
Syringe size | 10, 20, 30, 50ml |
Dialysis fluid circuit
Dialysis fluid flow range
Selectable: 300-800 mL/min
Dialysis fluid temperature
Selectable: 34.0℃ to 40.0℃
Dialysis fluid conductivity
Range:12 to 16 mS/cm (25℃)
Accuracy:±0.1 mS/cm
Acid concentration dialysis fluid
Default mixing ratio:1+34 (others possible)
Range:125 to 150 mmol/L
Bicarbonate concentration dialysis fluid
Default mixing ratio:1+27.6 (others possible)
Range: -8 to +8 mmol/L bicarbonate
Ultrafiltration
UF rate | 0ml/h~4000ml/h |
Accuracy | ±1% |
Allowed dialyzer UF factor | unlimited |
Parameter displayed | UF goal, UF time, UF rate, UF volume |
Blood leak detector
Sensitivity: ≤0.35 mL blood/min (HCT=32)
KT/V
Calculation
Disinfection and cleaning programs
Rinse
Temperature/flow: 30 to 60℃ / 300 to 800ml/min
Hot Rinse (recirculation)
Temperature/flow:30 to 85℃ / 300 to 800ml/min
Hot disinfection with chemical
Temperature/flow: 30 to 85℃/ 300 to 800ml/min
Various program combinations are selectable
Reason To Buy
Closed volume balance chamber
ne-key low-speed ultrafiltration can set low-speed UF
Support isolated UF
Parameters
Product Size:142cm x 49cm x 51cm
Materials:ABS
Country of origin: CANADA
Packing Desrciption
Packing Size:63*73*160CM 118kg
Package:wooden case