Description
Neonatal Radiant Warmer for Newborn With 3 Control Modes AG-IRW002
Model:AG-IRW002
Brand: Advanced Health Canada
Country of origin: CANADA
AG-IRW002 neonatal radiant warmer is used to provide warmth and improve thermal stability for newborn infants with a microprocessor-based servo-controlled temperature system. The device uses an infrared heating element to emit heat, which is then absorbed by the infant’s body. Radiant warmers are typically used in hospital nurseries and delivery rooms, as they provide a safe and effective way to keep newborns warm during their first few hours of life.
This neonatal radiant warmer is equipped with audible and visual alarm functions. You can check the power failure, temperature deviation, temperature sensor failure, skin temperature failure, and over-temperature quickly from alarming, which is very convenient.
Function
- Microprocessor-based serve controlled temperature system
- The microprocessor-controlled unit allows for three modes: pre-warm, manual and automatic
- APGAR timer to record therapy time
- Audible and visual Alarm functions:
Power failure, temperature deviation, temperature sensor failure, skin temperature failure, over temperature
- LED observation light adjustable, brightness adjustable
- Heater head can be adjusted ±90°horizontally
- Convenient X-ray cassette board under infant bed
- Tilt angle of infant bed is adjustable
- Four Transparent protectors folded with 2 infusion seals
- With RS-232 connector,2 trays, and 2 drawers
Specification
Power supply | AC110/220V 60/50Hz |
Power input | 1000VA |
Operating conditions | Environment temperature:18℃~30℃ Environment relative humidity:30%~75% Atmospheric Pressure:700~1060hpa Environment air velocity of flow: <0.3m/s |
Skin Temperature control range | 32℃~38℃ |
Skin temperature control accuracy | ≤0.5℃ |
Skin temperature sensor accuracy | ±0.3℃ |
Mattress temperature uniformity | <2℃ |
Infant Bed tilt angle | ±10° |
Warm-up time (from 25℃) | <30min |
Heater head horizontal | ±90° |
Distance from the heater to the mattress | 80cm |
Mattress size | 67cmX54 |
Timer range | 0~99h59min |
Package Details
Each unit is packed with one plywood case
Packing Size:118*90*87cm
N.W.:75kg G.W.:100kg
Transport and storage
Environment temperature -40℃~+55℃
Environment relative humidity ≤95%
Atmospheric Pressure 50-1060hpa
Reason to Purchase
Microprocessor-based serve controlled temperature system
The microprocessor-controlled unit allows for three modes: pre-warm, manual and automatic
APGAR timer to record therapy time
Audible and visual Alarm functions
LED observation light adjustable, brightness adjustable
Heater head can be adjusted ±90°horizontally
Convenient X-ray cassette board under infant bed
Tilt angle of infant bed is adjustable
Four Transparent protectors folded with 2 infusion seals
With RS-232 connector,2 trays, and 2 drawers
Parameters
Country of origin: Canada
Packing Description
Packing Size: 1100*780*860mm90kg
Package: Wooden crate