Description
Premature Neonatal Incubator AG-IIR001B
Model:AG-IIR001B
Brand: Advanced Health Canada
Country of origin: CANADA
AG-IIR001B Premature Neonatal Incubator features a microprocessor-based servo-controlled temperature system for your peace of mind. You’ll be able to easily adjust the humidity levels as needed, and the set temperature, air temperature, and heating power are all displayed separately on LED screens. Plus, this neonatal incubator features self-testing and various failure alarms with both audible and visual indicators.
Besides, this neonatal incubator is the basic baby incubator for NICU. You can adjust the inclination of the infant bed and get triple protection for OVER-temperature with a separate cut-off device, which is a more safe system.
Functions
- Microprocessor-based servo-controlled temperature system
- Control modes: Air mode
- Humidity is adjustable continuously
- Set temperature, air temperature, heating power are displayed separately by LED
- Self-testing function, various failure alarms by audible and visual
- Alarm function: Power failure, Over temperature, Temperature deviation, Fan failure, Temperature sensor failure
- >37℃ temperature set function
- Triple protection for over temperature with separate cut-off device, more safety system
- The inclination of the infant bed is adjustable
- Single wall hood,4 operating windows, and 2 iris ports,3 infusion seals independent locking device for front door
- RS232 connector, Oxygen inlet,1 tray
Specification
Model | AG-IIR001B Premature Neonatal Incubator |
Power | ~ 220V 50Hz |
Input power | 650VA (including power output socket power: 200VA) |
Temperature | 20 ° C ~ 30 ° C |
Humidity | 30% RH ~ 75% RH |
Air pressure | 700hPa ~ 1060hPa |
Air velocity | less than 0.3m/s |
Box temperature | 25 ° C ~ 37 ° C; 37.1 ° C ~ 38 ° C |
Warm-up time | ≤ 45 minutes |
Box temperature over temperature | 38 ° C (power off the heater) sound and light alarm |
The second thermal cut-off device over-temperature alarm | 40 ° C (cut off the heater power supply) sound and light alarm |
Box temperature deviation | ±3.0 °C (power off the heater at +3.0 °C) sound and light alarm |
Sensor alarm | When the box temperature sensor is open or short circuit, the heater power supply is cut off, and the sound and light alarm are given |
Power interruption alarm | power interruption, sound and light alarm |
Fan failure | The fan stops and its sensor system fails, the sound and light alarms, and the heater power is cut off |
The maximum carbon dioxide concentration | 0.4% (tested in accordance with the provisions of Article 105.1 of GB11243-2008) |
Less than 55dB (A-weighted) |