Skip to content Skip to footer

Z-arm digital radiographic equipment  AG-Staray 5000

Compare
Category: Product ID: 13206

Description

Model:AG-Staray 5000 Z-Arm

Brand:- Advanced Health Canada

Country of origin:- Canada

Z-arm digital radiographic equipment  AG-Staray 5000

This X-ray device uses high-energy X-rays to penetrate the body and create images of internal organs and bones.The resulting images can be used to diagnose and treat medical conditions. It is designed as a Z-Arm, making it easier and more convenient to move and operate.

standard

1 flat panel detector
1.1 Amorphous silicon flat panel detector
1.2 Effective pixels: 90,000
1.3 Pixel matrix: 3071*3071 pixels
1.4 Quantization depth: 16 bits
1.5 Effective area: 17″*17″
1.6 Pixel size: 140μm
1.7 Spatial resolution: 3.7 L/mm
1.8 Imaging time:7.6s
2 Mechanical structure: scythe arm(type Z) 
2.1 Stand weight: 210kg (the whole machine weight ≤ 288kg)
2.2 Vertical range(scythe arm): 600mm ~ 1600mm(±5%)
2.3 Rotation range of the scythe arm: -45°~ +135°(±2°)
2.4 SID (vertical and horizontal) can be adjusted electronically, the range: 1000mm~1800mm(±5%)
2.5 Rotation range of the tube assembly :-15°~+15°(±2°)
2.6 Rotation range of the detector:-45°~+45°(±2°)
2.7 One-key flat bed position, one-key chest radiograph position
2.8 9.5 “LCD touch screen
2.9 Minimum height of the equipment room:2.4m
2.10 The tube and detector move synchronously to maintain the balance of the stand
2.11 The detector end can independently control the movement of the stand
3 High Voltage Generator 
3.1 High voltage generator smart network voltage real-time monitoring system(smart monitor)
3.2 Power: 50kW
3.3 kV range: 40kV-150kV
3.4 mA range: 10mA-630mA
3.5 mAs range: 0.1mAs-630mAs
3.6 Time range for loading: 1ms – 6300ms
3.7 Inverter frequency: 60-200kHz
4 X-ray Tube 
4.1 Focus size:0.6mm/1.2mm
4.2 Focus power: small focus: 20kW large focus: 50kW
4.3 Maximum heat capacity:300kHU
4.4 Maximum peak voltage:150kV
5 Filter grid 
5.1 Size: 18 inch×18 inch
5.2 Ratio:≥10:1
5.3 Electrical mode
6 LED Collimator
6.1 The time limit of indicator:30±3s
6.2 Radiation field light: 150W, 24VAC
6.3 Radiation leakage:≤0.54mGy/h
7 Table 
7.1 Table height: 70cm (±5cm)
7.2 Table length: 200cm (±5cm)
7.3 Table width: 70cm (±5cm)
7.4 Load bearing: 135kg
8.2 Software function(patient management) 
8.2.1 Remote direct access to patient information in RIS with worklist protocol;
Manually create the patient examination information;
8.2.2 Emergency quick registration;
8.2.3 Simple, advanced, or custom data query methods;
8.2.4 Inquiry and management of historical image data;
8.2.5 The image CD burning in Dicom standard ,can be viewed on any standard image workstation;
8.2.6 Detection of disk space, automatic cleaning of old check data;
8.2.7 Dicom transmission of image and seamless connection with PACS;
8.2.8 Support diagram text report, carry report library;
8.2.9 Print patient reports and exposure times can be displayed in the list of patients; The original image is easy to view.
8.3 Software function(software direct exposure control)
8.3.1 Support customization for dose template;
8.3.2 Selection part and position template, automatically bring out the matching dose; Selection shape of the patient, automatically select the matching dose and adjust to the dose online;
8.3.3 Control the size of focus;
8.3.4 Display generator’s status transparent;
8.3.5 Refusal and acceptance of images;
8.3.6 Support automatic sending of images.
8.4 Software function(image processing)
8.4.1 Supports dual or multi-screen images display;
8.4.2 Manually/automatically/preset window width and window level, partial window width and window level;
8.4.3 Operation positive and negative of image, flip image, rotation image, scaling image, and roaming;
8.4.4 Automatic or manual addition of image information;
8.4.5 Line, angle, rectangle, ellipse, polygon, and other measuring tools;
8.4.6 Balance tissue, enhancement contrast, optimization dose;
8.4.7 Enhancement edge: automatic recognition and analysis of images, enhance edge sharpness.
8.4.8 Preview the post-processing image 1:1: the doctors make a more intuitive diagnosis in image optimization;
8.4.9 CAD View: just click the mouse, and doctors can see the details of the image more clearly so that doctors can make a more accurate diagnosis.
8.5 Software function (film printing) 
8.5.1 Set film properties, image layout, and printing mode;
8.5.2 Typeset quickly by manual/automatic;
8.5.3 Select any camera within the network;
8.5.4 Customization of patient information and display location; Support for queue management;
8.5.5 Support for setting print priority.
9 Optional functions 
9.1 AEC — Automatic exposure control technology
Accurate and efficient dose management;
Improve the image quality;
Easy Operation.
9.2 Image stitching:
Seamless stitching, smooth and natural.
9.3 EE-PACS:
A very powerful PACS system, using B/S architectural design and based on international DICOM and HL7standards. It is designed and optimized for high workflow efficiency and productivity, as well as friendly and intuitive user interfaces. It provides a rich set of modules to meet your daily needs.