Description
JHM-2028M Hemodialysis Machine
Model:JHM-2028M
Brand:- ADVANCED HEALTH CANADA
Country of origin:- CANADA
- Combine with Hemodialysis, Hemoperfusion, ISO UF, Hemoperfusion, Plasa Exchange all-in-one
• Multi-language LCD touch screen with high definition display interface
Safety
- Air bubble monitor: optical and ultrasonic double control, can monitor blood levels and accumulate air bubble
• With safe and sensitive blood leakage monitor device
• Complete water-way and electric way apart design, individual waterway control system to ensure the security
• Dialysate temperature with high precision, safety control at 35-39℃
• Protection from intercross infection, fluid supply loop, and return loop are completely divided during disinfection
• Avoid pollution of the whole machine in the case of mis-sucking disinfection liquid
• Conductivity control and protection: conductivity A, mix. conductivity, water outlet conductivity, insure patient’s security
• Adjustable Na+ curve profile, with the multiplicate optional auto-adjust program, can realize individual dialysis and ensure patient’s safety
Practicability
- In-built battery backup to support 30 minutes after power off
• Disinfection: Rinse, hot disinfection, and chemic disinfection.Circulated and closed disinfection system
• Automatically turn off the machine once the disinfection process completes
• Diameter of blood pump can be adjusted to be flexible for adults and child
• Be applicable for various concentration ratio formula
• Store treatments information of curve profile
• Full function digital self-test process
• With visual and auditive alarm, character message shows alarm item and troubleshooting on screen
Specification
| Extracorporeal circulation system | |
| Blood pump flow | 20-620ml/min |
| Blood pump segment Dia. | 6.4 and 8mm adjustable |
| Heparin pump flow scope | 0~10 ml/h |
| Syringe | 10m/20ml/30ml;20ml/30ml/50(optional) |
| Arterial and pressure monitor | -300- +400mmHg(土10mmHg) |
| Venous pressure monitor | -50-+300mmHg(士10mmHg) |
| Air bubble detector | Infrared and ultrasound detection |
| Dialysate system | |
| Dialysate flow | 300-800ml/min linearly adjustable(+ 10%,-5%) |
| Dialysate temperature scope | 35.0-39.0℃ |
| Conductivity | 12.3-15.8mS/cm |
| Na+ adjustment scope | 136-145mmol/L |
| HCO3~adjustment scope | 28.0-42.0mmol/L |
| Bicarb Cartridge | Optional |
| Blood leakage detection | |
| Method | Photoelectnidty detection |
| Ultrafiltration controlling system | |
| Ultrafiltration ratio | 0-4000ml/h |
| Pump volume accuracy | 士1% |
| Disinfection and rinse | |
| Rinse and heat disinfection (above 90℃) | |
| Chemical disinfection | Peracetic acid |
| Heat chemical disinfection | Citric acid |
| Other parameters | |
| Dimension(Length*width*height) | 370mm*340mm* 1450mm |
| Weight | 90Kg |
| Power supply voltage | 100-240V Ac士10% 50-60HZ |
| Power | 1.7KW |
| Back-up battery | At least 30 minutes working after electricity cut |
| Working environment | Temperature:10- 30 Relative humidity no higher than 70% |
| Water supply temperature | Temperature:5-30C |
| Dialysate formula | Great compatibility be applicable to various concentration ratio formula |
| Pressure | 0.12-0.6Mpa |
Reason To Buy
Parameters
Country of origin:- CANADA
Packing Desrciption