Kidney Dialysis Machine Hemodialysis Machine JHM-2028A
Model:JHM-2028A
Brand:- ADVANCED HEALTH CANADA
Country of origin:- CANADA
Integrity
♦ Combine with Hemodialysis. Hemoperfusion, ISO UF.Hemoperfusion, Piasa Exchange all-in-one
♦ Multi-language LCD touch screen with high definition display Interface
♦ Double pump: blood pump and spare pump can be replaced by each other, compatible to different size diameter bloodline
Practicability
♦ In-built battery backup to support 30 minutes after power off
♦ Disinfection: Rinse,hot disinfection and chemic disinfection. Circulated and closed disinfection system Automatically turn off the machine once the disinfection process completes
♦ Diameter of blood pump can be adjusted to be flexible for adults and child
♦ Be applicable for various concentration ratio formula
♦ Store treatments information in form of curve profile
♦ Full function digital self-test process
♦ With visual and auditive alarm, character message shows alarmism and troubleshooting on screen
Safety
♦ Air bubble monitor: optical and ultrasonic double control. can monitor blood levels and accumulate air bubble
♦ With safe and sensitive blood leakage monitor device
♦ Complete water-way and electric way apart design, individual waterway control system to ensure the security
♦ Dialysate temperature with high precision.safety control at 35-39°C
♦ Protection from intercross infection, fluid supply loop, and return loops completely divided during disinfection to avoid pollution of the whole machine In the case of mis-sucking disinfection liquid
♦ Conductivity control and protection: conductivity A.mixed conductivity, water outlet conductivity, insure patient’s security
♦ Adjustable Na+ curve profile with the multiplicate optional auto-adjust program, which can realize individual dialysis and ensure patient safety.
♦ Out-built UF test port, can test the precision of UF pump and running status
Specification
Volume: (length x width x height) 370mmx340mm x 1420mm | Inflow temperature: 5-30℃ |
Weight: About 90kg | Environment temperature: 10 -38°C |
Power supply voltage: AC220V±10% AC 110V(optional) |
Relative humidity:≤80% |
Frequency:50HZ-60 HZ | Rinse/disinfection: chemical disinfection(citric acid, peracetic acid, and sodium hypochlorite) |
Power:1500W | Hot rinse:≥80℃ |
Blood pump/spare pump Flux:20-460ml/min(Φ6mm) 20-620 ml/min(Φ8mm) |
Back-up power supply: last for 15-30min after electric-cutHe |
Heparin pump Flux:0.1mL/h-10mL/h(±5%) Precise: 0.1ml/h Injector size: 10ml/20ml/30ml 20ml/30ml/50ml(optional) |
Conductivity: 12.3mS/cm-15.8mS/cm(±0.1 mS/cm) UF flow scope:0-4000ml/h ISO UF flow scope:0-4000ml/h(±30ml/h) TMP Scope: 100mmHg-+600mmHg(±20mmHg) |
Arterial pressure Display scope :-300mmHg-+400mmHg(±10mmHg) | Temperature: 35.0℃~39.0℃ Resolving rate:0.1 |
Venous pressure Display scope: -50 mmHg-+300mmHg(±10mmHg) |
Blood leakage monitor: over 1ml blood per liter dialysate(flow:500ml/min) Blood level monitor: ultrasonic sensor |
Dialysate Flow 300ml/min-800ml/min linearity adjustable (+10%) (-5%) |
Air bubble monitor Infrared and response threshold value: Single air bubble of 200µl exists when Blood flux is 200ml/min Inflow pressure:0.12MPa-0.6MPa |
Introduction
Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange. Pure UF treatments; touch screen display, with Na+ and UF profiles, backup power supply, Kt/V, HCO3-adjustment, single needle, acetate treatment
Clinical Application
♦ Hemodialysis therapy
Mainly suitable for all kinds of acute and chronic kidney failure patient
♦ Pure ultrafiltration therapy
Mainly suitable for patients with excessive water stored in the body due to acute, chronic kidney failure or incomplete heart function
♦ Hemoperfusion therapy
Mainly applies in acute drug poisoning, especially those accompanied by the brain function barrier or stupor,liver and kidney function barrier, old patients, and those who takes medicine oversized which had achieved the toxicant lethal dose density or exceed 30% of their own elimination ability
♦ Plasma exchange therapy
Mainly suitable for the immunity diseases; acute nephritis, lupous nephritis, frequent myeloma nephrosis, serious myasthenia, acute liver function failure, thyroid gland crisis, ethnic hypercholesterolemia, HVS, etc.
Feature
♦ Bicarb Dry Powder cartridge (optional)
Producing bicarbonate dialysis solution on line to reach a pure and full-complete dialysis treatment.
♦ Na+and UF profiling
Be applicable for reducing the cases during dialysis treatment such as low/high pressure, muscle convulsion, headache, nausea, vomit and the occurrence rate of high pressure after dialysis treatment etc
♦ Kt/V function
The sufficiency of dialysis can be reflected by Kt/V
♦ HCO3 adjustment
Be applicable for serious acid toxicosis patient.
Be capable to calibrate the acid toxicosis status according to the patient’s state of illness
♦ Pyrogen filter port(optional)
Completely filtrating the remained bacteria and endotoxin
♦ Network connection(optional)
One computer can audit and -control the treatment of maximum of 20 units of hemodialysis machine
Reason To Buy
Parameters
Country of origin:- CANADA
Packing Desrciption